Citrix Provisioning Services Show Connected Devices Timeout Error

Citrix Provisioning Services Show Connected Devices Timeout Error

PVS 7 Show Connected Devices Timeout Error

If your having issues viewing the target devices connected to PVS by clicking on “Show Connected Devices” you will need to update the the Registry entries below. We experienced issues where it would take several minutes to show the connected devices list and some times PVS would populate quickly and other times we would get a 4002 error.

  1. Go to Run> Type in Regedit and click Ok.
  2. Under HKLM\software\citrix\provisioningServices\Manager key, create registry DWORD RelayedRequestReplyTimeoutMilliseconds, and set it to 50 ms Decimal
  3. Create a DWORD RelayedRequestTryTimes and set it to 1.
    Default is 2.
  4. Open the PVS Server console and test by selecting the Show Connected Devices command.

Citrix Reference Article- http://support.citrix.com/article/CTX133877

Share or Save this:
Share